Call To OrderItem I.

Call To Order

Roll CallItem II.

Roll Call

Public CommentItem III.

Public Comment

Consent ApplicationsItem IV.

Consent Applications

Old BusinessItem a)

Staff notes this application was continued at the September 9, 2026 AHBR meeting.

Old BusinessItem b)

A site visit will take place on September 22, 2026.

Old BusinessItem c)

Staff notes the applicant has submitted a revised west-side elevation depicting a more consistent window design for the Boards consideration.

Old BusinessItem d)

Appendix 1 (6) of the Secretary of Interior Standards state “deteriorated historic features shall be repaired rather than replaced. Where the severity of deterioration requires replacement of a distinctive feature, the new feature shall match the old in design, color, texture, and other visual qualities and, where possible, materials. Replacement of missing features shall be substantiated by documentary, physical, or pictorial evidence.”

Old BusinessItem e)

Staff notes the applicant is seeking approval for JELD-WEN Siteline series windows for the replacement of historic materials. Staff notes that the proposed window series is not currently included on the AHBR-approved materials list for replacement windows on historic structures. Suggest the applicant bring a sample window to the meeting for the Board to review.

Old BusinessItem f)

Question the appropriateness of the proposed transom windows on the historic carriage house.

Old BusinessItem a)

Staff notes this application was continued at the September 9, 2026 AHBR meeting.

Old BusinessItem b)

Staff notes the applicant has submitted revised elevations depicting a more consistent window type and applied foundation for the Boards consideration.

Old BusinessItem c)

Section IV-4 (d)(3) of the Architectural Design Standards state that the materials used in any mass must be applied consistently on that mass on all sides of the structure. Staff notes the applicant is proposing brick siding on the left and rear elevations that would not be applied around the entire mass.

Old BusinessItem d)

Section IV-4 (e)(4) of the Architectural Design Standards state that the building shall have a typical window used for most windows. Staff notes a mix of fixed and double hung windows are proposed.

Old BusinessItem e)

Section III-1(g)(8) of the Architectural Design Standards state that large expanses of blank wall are to be avoided. Fenestration placement should be at a maximum of approximately every 12 feet. Question if additional fenestration is needed on the left-side elevation to better meet the requirement.

New BusinessItem a)

Staff has prepared the attached memo with case overview and recommendations.

New BusinessItem a)

Verify proposed roofing material to match existing.

New BusinessItem b)

Verify proposed foundation material to match existing.

New BusinessItem c)

Submit a roof plan.

New BusinessItem a)

Section III-1 (a)(4) of the Architectural Design Standards states that attached garages shall not face the street except for new development with a front yard depth of 130 feet or more. Staff notes an existing front facing garage would be rebuilt due to storm damage. Staff has determined a variance is not required under Section 1206.05(f)(1) of the Land Development Code. The garage door width would not be expanded.

New BusinessItem b)

Section IV-3 (b)(1) of the Architectural Design Standards states that wings may not be larger or taller than the main body of the structure, but they may be the same height. Verify the proposed garage addition is not taller than the existing house.

New BusinessItem c)

Section III-1 (g)(8) of the Architectural Design Standards states that large expanses of blank wall are to be avoided. Fenestration placement should be at a maximum of approximately every 12 feet. Revise elevations to depict additional fenestration on the south side elevation to better meet the requirement.

New BusinessItem d)

Section IV-4 of the Architectural Design Standards state that additions should be designed to be compatible with the main structure by incorporating materials and a foundation to match. Revise elevations to depict foundation material to match the existing around the proposed garage addition.

New BusinessItem a)

Staff notes the existing peaked dormer received administrative approval on September 16, 2024.

New BusinessItem b)

Upon final inspection, staff observed a deviation from the final approved plans. Staff notes both horizontal siding and board and batten siding were installed within the peaked dormer in place of the approved green shake siding. The applicant has requested the AHBR consider the proposed dormer material change. Additionally staff notes the applicant is proposing to install new board and batten siding material within the existing west-side elevation dormer and bump-out to