Planning Commission - Regular Meeting

Lehigh County
Tuesday, October 13, 2026Official site

About this meeting

Government Body
Planning Commission
Meeting Type
Planning Commission
Location
Allentown, PA
Meeting Date
October 13, 2026

Video will appear here as soon as Allentown Planning Commission posts it — usually within a day of the meeting

Tuesday, October 13, 2026

6 items on the agenda.

Call to Order•Item 1

Approval of Minutes from the Public Meeting of September 8, 2026

Sidewalk Postponement•Item 2

Project: 932 Walnut Street

Applicant: Barry isett & Associates Location: 932 W Walnut Street Description: Request to postpone requirements of §545-13 for the maintenance and replacement of existing curbs and sidewalks. File: S 26-02

Land Developments•Item 3

Bridgeview Academy Additions

Applicant: Allentown School District Location: 265 Lehigh Street Description: Construction of a 2-story addition and a gymnasium addition with a pedestrian bridge and associated site improvements. File: LMA-2026-000013 (Preliminary/Final) Waivers requested: from SALDO Streetscape Area Regulations: §350-13.F(1): Alternative Compliance, Timing: An alternative method... such as a fee-in-lieu... may be approved provided pedestrian continuity is provided within no more than one year from completion of construction §350-13.G(2): Street Tree Area: A minimum 4-foot-wide street tree area, between the face of curb and the sidewalk, is required. §350-13.H(1): Minimum Streetscape: Applies all regulations in §13.G. §350-13.H(3)(a): Pavement Design: Paving materials and a pattern is required for each street. §350-13.H(3)(d): Lighting: Both pedestrian and vehicular lighting must be specified and locations and quantities noted.

Land Developments•Item 4

Project: 2401 W Emaus Avenue - Data Center

Applicant: Quantm Group, LLC Location: 2401 W Emaus Avenue Description: Amended Preliminary / Final land development application of a previously approved 224,000 SF warehouse building to be revised into a Data Center use, adding an electrical substation, sound attention walls and associated site improvements. File: LMA-2022-00010 (Preliminary / Final - Amended) - Resubmission Waivers Requested: from existing conditions pending confirmation of SALDO §350-26.D: No opening from building shall be less than 1 foot above the curb elevation. §350-28.C(8): The bottom of the pond is to be sloped towards the outlet structure. §350-28.E(3): Storm sewers shall be required to have a minimum diameter of 15 inches and shall be made of reinforced concrete unless otherwise noted by the City Engineer, Sewers shall be installed in sufficient slopes to provide a minimum velocity of 3 feet per second and a maximum of 3 feet per second. §350-32.A: An easement of at least 20 feet in width must be provided along side and rear lot lines, labeled "General Utility Easements".